Bai BA-220 Especificações Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
BAI Reader Connections
Wiring for power connections to Model BA-220 DualBeam barcode reader:
Model BA-220 is powered by 115VAC @ 0.8A, refer to local electrical code for proper AC
wiring. Requires 3 wires (Hot, Neutral, Ground) for AC power connection.
Model BA-220-24 is powered by 24Vdc @ 2.5A. Recommend using 18 AWG stranded copper
wire for distances up to 200'. For longer distances, use 16 AWG wire. Requires 2 wires,
V+ and V-, for DC power connection.
Wiring for power connections to Model BA-440 DualBeam barcode reader:
Model BA-440 is powered by 24Vdc @ 1.5A. Recommend using 18 AWG stranded copper
wire for distances up to 200'. For longer distances, use 16 AWG wire. Requires 2 wires,
V+ and V-, for DC power connection.
Wiring for Wiegand Communications:
Recommend 18 AWG stranded copper wire with shield for distances up to 400'. Requires 3
wires (Ground, Data 1, Data 0) for communications connection.
Wiring for other inputs and relay outputs (if used):
Recommend 18 AWG stranded copper wire for distances up to 400'.
Ver. 1.8 Barcode Automation, inc 800-528-9167 FAX: 407-327-6172 19
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 27 28

Comentários a estes Manuais

Sem comentários